PRODUCT IDENTIFICATION, The model number is used for positive identification of component parts used in manufacturing Please use this number. when requesting service or parts information,G S C 14 036 1 A A. Brand Name Minor Revision,G Goodman A Initial Release. Standard Feature Set Models,S Goodman Deluxe,High Feature Set Models Major Revision. A Initial Release,Product Family,S Split System,Electrical.
1 208 230V 60Hz 1ph,Product Type,3 208 230V 60Hz 3ph. C Condenser R 22 4 460V 60Hz 3ph,X Condenser R 410A. H Heat Pump R 22,Z Heat Pump R 410A,Nominal Capacity. 018 1 5 tons,024 2 tons,SEER 036 3 tons,042 3 5 tons. SEER Rating 048 4 tons,060 5 tons,090 7 5 tons,120 10 tons.
HIGH VOLTAGE, WARNING DISCONNECT ALL POWER BEFORE SERVICING MULTIPLE POWER. SOURCES MAY BE PRESENT FAILURE TO DO SO MAY CAUSE PROP. ERTY DAMAGE PERSONAL INJURY OF DEATH, ONLY INDIVIDUALS MEETING THE REQUIREMENTS OF AN ENTRY. LEVEL TECHNICIAN AS SPECIFIED BY THE AIR CONDITIONING AND. WARNING REFRIGERATION INSTITUTE ARI MAY USE THIS INFORMATION AT. TEMPTING TO INSTALL OR REPAIR THIS UNIT WITHOUT SUCH BACK. GROUND MAY RESULT IN PRODUCT DAMAGE PERSONAL INJURY OR DEATH. PRODUCT IDENTIFICATION, The model number is used for positive identification of component parts used in manufacturing Please use this number. when requesting service or parts information,GSC140181A. GSC140241A,GSC140301A,GSC140361A,GSC140421A,GSC140481A.
GSC140601A, Indicates minor revision is not used for order entry or inventory management. TO PREVENT THE RISK OF PROPERTY DAMAGE PERSONAL INJURY. WARNING OR DEATH DO NOT STORE COMBUSTIBLE MATERIALS OR USE GASO. LINE OR OTHER FLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF. THIS APPLIANCE, DO NOT CONNECT OR USE ANY DEVICE THAT IS NOT DESIGN CERTI. WARNING FIED BY GOODMAN FOR USE WITH THIS UNIT SERIOUS PROPERTY. DAMAGE PERSONAL INJURY REDUCED UNIT PERFORMANCE AND OR. HAZARDOUS CONDITIONS MAY RESULT FROM THE USE OF SUCH NON APPROVED DEVICES. PRODUCT DESIGN, GSC 14 SEER models are available in 1 1 2 through 5 ton. sizes They are designed for 208 230 volt single phase appli. The condenser air is pulled through the condenser coil by a. direct drive propeller fan This condenser air is then dis. charged out of the top of the cabinet RECOMMENDED B OK. These units are designed for free air discharge so no addi. tional resistance like duct work shall be attached B B B. The suction and liquid line connections on present models. are of the sweat type for field piping with refrigerant type cop A AA AA. per Back seating valves are factory installed to accept the. field run copper The total refrigerant charge for a normal in C C OK. stallation is factory installed in the condensing unit GSC AA AA AA OK. units are charged for the matching evaporator coil and a 15 OK. foot refrigerant line set, Systems should be properly sized by heat gain and loss. calculations made according to methods of the Air Condi. tioning Contractors Association ACCA or equivalent It is C C. the contractors responsibility to ensure the system has ad. equate capacity to heat or cool the conditioned space. GSC14 condensing units use Copeland Compliant Scroll. compressors Due to their design Scroll compressors are Special consideration must be given to location of the con. inherently more tolerant of liquid refrigerant densing unit s in regard to structures obstructions other. units and any all other factors that may interfere with air. NOTE Even though the compressor section of a Scroll com circulation Where possible the top of the unit should be. pressor is more tolerant of liquid refrigerant continued flood completely unobstructed however if vertical conditions re. back or flooded start conditions may wash oil from the bear quire placement beneath an obstruction there should be a. ing surfaces causing premature bearing failure minimum of 60 inches between the top of the unit and. Copeland Compliant Scroll compressors use white oil which the obstruction s The specified dimensions meet require. is compatible with 3GS 3GS oil may be used if additional oil ments for air circulation only Consult all appropriate regula. is required tory codes prior to determining final clearances. The GSC condensers use new generation scroll compres Another important consideration in selecting a location for. sors These compressors have an internal equalization mecha the unit s is the angle to obstructions Either side adjacent. nism and an anti counter rotation device which allow the scrolls the valves can be placed toward the structure provided the. side away from the structure maintains minimum service clear. to equalize in approximately second at shut down, ance Corner installations are strongly discouraged.
Operating pressures amp draws and minimum circuit am. DO NOT locate the unit, pacity may differ from standard reciprocating compressors. This information may be found in the Cooling Performance Directly under a vent termination for a gas appliance. Data section and should be reviewed prior to installation of Within 3 feet of a clothes dryer vent. the condenser Where the refreezing of defrost water would create a. Where water may rise into the unit,Model Dimensions W x D x H. GSC140181A 26 x 26 x 32,GSC140241A 26 x 26 x 32,GSC140301A 29 x 29 x 32. GSC140361A 29 x 29 x 34,GSC140421A 35 x 35 x 38,GSC140481A 35 x 35 x 38. GSC140601A 35 x 35 x 38,CONDENSING UNIT SPECIFICATIONS.
GSC140181A GSC140601A,GSC140181A,GSC140241A,GSC140301A. GSC140361A,GSC140421A,GSC140481A,GSC140601A, Cooling Capacity BTUH 18 000 24 000 30 000 36 000 42 000 48 000 60 000. Compressor SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL. R L Amps 7 7 10 4 12 2 14 1 14 7 19 2 19 8,L R Amps 40 3 54 0 63 0 68 0 77 0 104 0 137 0. Condenser Fan Motor,Horsepower 1 12 1 12 1 6 1 4 1 4 1 4 1 4. F L Amps 0 6 0 6 1 1 1 5 1 5 1 5 1 5, Liquid Line Inches O D 3 8 3 8 3 8 3 8 3 8 3 8 3 8.
Suction Line Inches O D 3 4 3 4 3 4 7 8 7 8 7 8 1 1 8. Refrigerant Charge 130 0 135 0 140 8 155 0 180 0 195 0 285 0. Power Supply 208 230 60 1 208 230 60 1 208 230 60 1 208 230 60 1 208 230 60 1 208 230 60 1 208 230 60 1. Minimum Circuit Ampacity 10 2 13 7 16 3 19 1 19 9 25 5 26 3. Maximum Overcurrent Device 15 20 20 30 30 40 40,Electrical Conduit Size. Power Supply Inches 1 2 or 3 4 1 2 or 3 4 1 2 or 3 4 1 2 or 3 4 1 2 or 3 4 1 2 or 3 4 1 2 or 3 4. Approximate Shipping Weight 173 173 208 209 258 270 271. Up to 35 in equivalent line length, Wire size should be determined in accordance with National Electrical Codes extensive wire runs will require larger wire sizes. May use fuses or HACR type circuit breakers of the same size as noted. NOTE This data is provided as a guide it is important to electrically connect the unit and properly size fuses. circuit breakers and wires in accordance with all national and or local electrical codes Use copper wire only. EXPANDED PERFORMANCE DATA,COOLING PERFORMANCE DATA. COOLING OPERATION, MODEL GSC140181A CA F3131B6 TXV Design Subcooling ARI 95 F Conditions 9 3 F the Serv Valve. Outdoor Ambient Temperature,65 75 85 95 105 115,Entering Indoor Wet Bulb Temperature.
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71. MBh 17 6 18 3 20 0 17 2 17 9 19 6 16 8 17 4 19 1 16 4 17 0 18 6 15 6 16 2 17 7 14 4 15 0 16 4. S T 0 73 0 61 0 42 0 75 0 63 0 44 0 77 0 65 0 45 0 80 0 67 0 46 0 83 0 69 0 48 0 84 0 70 0 48. Delta T 18 15 11 18 15 12 18 15 12 18 15 12 18 15 12 16 14 11. 675 KW 1 27 1 29 1 32 1 35 1 37 1 41 1 42 1 45 1 49 1 48 1 51 1 55 1 54 1 56 1 61 1 58 1 61 1 66. AMPS 4 0 4 1 4 3 4 3 4 4 4 6 4 7 4 8 5 0 5 0 5 1 5 3 5 3 5 5 5 6 5 6 5 8 6 0. HI PR 134 144 152 150 162 171 171 184 194 195 210 221 219 236 249 242 261 275. LO PR 64 68 74 67 72 78 70 74 81 73 78 85 77 82 89 80 85 92. MBh 17 1 17 7 19 4 16 7 17 3 19 0 16 3 16 9 18 5 15 9 16 5 18 1 15 1 15 7 17 2 14 0 14 5 15 9. S T 0 69 0 58 0 40 0 72 0 60 0 42 0 74 0 62 0 43 0 76 0 64 0 44 0 79 0 66 0 46 0 80 0 67 0 46. Delta T 18 16 12 18 16 12 18 16 12 19 16 12 18 16 12 17 15 11. 70 600 KW 1 26 1 28 1 31 1 34 1 36 1 40 1 41 1 44 1 48 1 47 1 50 1 54 1 52 1 55 1 60 1 57 1 60 1 65. AMPS 4 0 4 1 4 2 4 3 4 4 4 5 4 7 4 8 4 9 5 0 5 1 5 3 5 3 5 4 5 6 5 6 5 7 5 9. HI PR 133 143 151 149 160 169 169 182 192 193 208 219 217 233 247 240 258 272. LO PR 63 67 73 67 71 77 69 74 80 73 77 84 76 81 89 79 84 92. MBh 15 8 16 4 17 9 15 4 16 0 17 5 15 1 15 6 17 1 14 7 15 2 16 7 14 0 14 5 15 9 12 9 13 4 14 7. S T 0 67 0 56 0 39 0 69 0 58 0 40 0 71 0 59 0 41 0 73 0 61 0 43 0 76 0 64 0 44 0 77 0 64 0 44. Delta T 19 16 12 19 16 12 19 16 12 19 16 12 19 16 12 17 15 11. 525 KW 1 23 1 26 1 29 1 31 1 34 1 37 1 38 1 41 1 44 1 44 1 47 1 51 1 49 1 52 1 56 1 54 1 57 1 61. AMPS 3 9 4 0 4 1 4 2 4 3 4 4 4 5 4 6 4 8 4 8 5 0 5 1 5 1 5 3 5 4 5 4 5 6 5 7. HI PR 129 138 146 144 155 164 164 177 187 187 201 213 210 226 239 233 250 264. LO PR 61 65 71 65 69 75 67 71 78 71 75 82 74 79 86 76 81 89. MBh 17 9 18 5 20 0 21 5 17 5 18 0 19 5 21 0 17 1 17 6 19 1 20 5 16 7 17 2 18 6 20 0 15 9 16 3 17 7 19 0 14 7 15 1 16 4 17 6. S T 0 83 0 74 0 56 0 36 0 86 0 77 0 58 0 37 0 88 0 79 0 60 0 38 0 91 0 81 0 61 0 40 0 94 0 84 0 64 0 41 0 95 0 85 0 64 0 41. Delta T 20 19 15 11 20 19 15 11 20 19 15 11 21 19 16 11 20 19 15 11 19 18 14 10. 675 KW 1 28 1 30 1 33 1 37 1 36 1 38 1 42 1 46 1 43 1 46 1 50 1 54 1 49 1 52 1 56 1 61 1 55 1 58 1 62 1 67 1 59 1 62 1 67 1 72. AMPS 4 1 4 2 4 3 4 4 4 4 4 5 4 6 4 8 4 7 4 9 5 0 5 2 5 1 5 2 5 3 5 5 5 4 5 5 5 7 5 9 5 7 5 8 6 0 6 2. HI PR 135 146 154 160 152 163 173 180 173 186 196 205 197 212 224 233 221 238 252 262 245 263 278 290. LO PR 64 68 75 80 68 72 79 84 71 75 82 87 74 79 86 92 78 83 90 96 80 86 93 100. MBh 17 4 17 9 19 4 20 8 17 0 17 5 19 0 20 3 16 6 17 1 18 5 19 9 16 2 16 7 18 1 19 4 15 4 15 8 17 2 18 4 14 3 14 7 15 9 17 1. S T 0 79 0 71 0 53 0 34 0 82 0 73 0 55 0 36 0 84 0 75 0 57 0 37 0 87 0 77 0 59 0 38 0 90 0 80 0 61 0 39 0 91 0 81 0 61 0 39. Delta T 21 19 16 11 21 20 16 11 21 20 16 11 21 20 16 11 21 20 16 11 20 18 15 10. GSC140181A, 75 600 KW 1 27 1 29 1 32 1 36 1 35 1 37 1 41 1 45 1 42 1 45 1 49 1 53 1 48 1 51 1 55 1 60 1 54 1 57 1 61 1 66 1 58 1 61 1 66 1 71. AMPS 4 0 4 1 4 3 4 4 4 3 4 4 4 6 4 8 4 7 4 8 5 0 5 2 5 0 5 1 5 3 5 5 5 3 5 5 5 6 5 8 5 6 5 8 6 0 6 2. HI PR 134 144 152 159 150 162 171 178 171 184 194 203 195 210 221 231 219 236 249 260 242 261 275 287. LO PR 64 68 74 79 67 72 78 83 70 74 81 87 73 78 85 91 77 82 89 95 80 85 93 99. MBh 16 1 16 5 17 9 19 2 15 7 16 2 17 5 18 8 15 3 15 8 17 1 18 3 15 0 15 4 16 7 17 9 14 2 14 6 15 8 17 0 13 2 13 5 14 7 15 7. S T 0 76 0 68 0 52 0 33 0 79 0 71 0 53 0 34 0 81 0 72 0 55 0 35 0 84 0 75 0 57 0 36 0 87 0 78 0 59 0 38 0 87 0 78 0 59 0 38. Delta T 21 20 16 11 22 20 16 11 22 20 16 11 22 20 16 11 22 20 16 11 20 19 15 10. 525 KW 1 24 1 26 1 30 1 33 1 32 1 34 1 38 1 42 1 39 1 42 1 45 1 49 1 45 1 48 1 52 1 56 1 50 1 53 1 57 1 62 1 55 1 58 1 62 1 67. AMPS 3 9 4 0 4 1 4 3 4 2 4 3 4 5 4 6 4 6 4 7 4 8 5 0 4 9 5 0 5 2 5 3 5 2 5 3 5 5 5 7 5 5 5 6 5 8 6 0. HI PR 130 140 148 154 146 157 166 173 166 179 189 197 189 203 215 224 213 229 242 252 235 253 267 278. LO PR 62 66 72 76 65 69 76 81 68 72 79 84 71 76 83 88 75 79 87 92 77 82 90 96. Entering Indoor Dry Bulb Temperature NOTE Shaded area is ACCA TVA conditions. EXPANDED PERFORMANCE DATA COOLING OPERATION,COOLING PERFORMANCE DATA. MODEL GSC140181A CA F3131B6 TXV Design Subcooling ARI 95 F Conditions 9 3 F the Serv Valve. Outdoor Ambient Temperature,65 75 85 95 105 115,Entering Indoor Wet Bulb Temperature. IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71. MBh 18 3 18 7 19 9 21 3 17 8 18 2 19 5 20 8 17 4 17 8 19 0 20 3 17 0 17 4 18 5 19 8 16 1 16 5 17 6 18 8 14 9 15 3 16 3 17 4. S T 0 91 0 85 0 69 0 52 0 94 0 88 0 72 0 54 0 96 0 90 0 74 0 55 1 00 0 93 0 76 0 57 1 00 0 97 0 79 0 59 1 00 1 00 0 80 0 59. Delta T 23 22 19 15 23 22 19 15 23 22 19 15 23 22 19 15 22 22 19 15 20 21 18 14. 675 KW 1 28 1 31 1 34 1 38 1 37 1 39 1 43 1 47 1 44 1 47 1 51 1 55 1 50 1 53 1 58 1 62 1 56 1 59 1 63 1 68 1 60 1 64 1 68 1 73. AMPS 4 1 4 2 4 3 4 5 4 4 4 5 4 7 4 8 4 8 4 9 5 1 5 2 5 1 5 2 5 4 5 6 5 4 5 6 5 7 5 9 5 7 5 9 6 1 6 3. HI PR 137 147 155 162 153 165 174 182 174 188 198 207 199 214 226 236 224 241 254 265 247 266 281 293. LO PR 65 69 75 80 69 73 80 85 71 76 83 88 75 80 87 93 79 84 91 97 81 86 94 101. MBh 17 7 18 1 19 4 20 7 17 3 17 7 18 9 20 2 16 9 17 3 18 5 19 7 16 5 16 8 18 0 19 2 15 7 16 0 17 1 18 3 14 5 14 8 15 8 16 9. S T 0 87 0 81 0 66 0 49 0 90 0 84 0 69 0 51 0 92 0 86 0 70 0 53 0 95 0 89 0 73 0 54 0 99 0 92 0 75 0 56 0 99 0 93 0 76 0 57. Delta T 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 21 18 15. 80 600 KW 1 28 1 30 1 33 1 37 1 36 1 38 1 42 1 46 1 43 1 46 1 50 1 54 1 49 1 52 1 56 1 61 1 55 1 58 1 62 1 67 1 59 1 62 1 67 1 72. AMPS 4 1 4 2 4 3 4 4 4 4 4 5 4 6 4 8 4 7 4 9 5 0 5 2 5 1 5 2 5 4 5 5 5 4 5 5 5 7 5 9 5 7 5 8 6 0 6 2. HI PR 135 146 154 160 152 163 173 180 173 186 196 205 197 212 224 233 221 238 252 262 245 263 278 290. LO PR 64 68 75 80 68 72 79 84 71 75 82 87 74 79 86 92 78 83 90 96 80 86 93 100. MBh 16 4 16 7 17 9 19 1 16 0 16 3 17 4 18 6 15 6 15 9 17 0 18 2 15 2 15 6 16 6 17 8 14 5 14 8 15 8 16 9 13 4 13 7 14 6 15 6. S T 0 84 0 78 0 64 0 48 0 87 0 81 0 66 0 49 0 89 0 83 0 68 0 51 0 92 0 86 0 70 0 52 0 95 0 89 0 73 0 54 0 96 0 90 0 73 0 55. The model number is used for positive identification of component parts used in manufacturing Please use this number when requesting service or parts information HIGH VOLTAGE DISCONNECT ALL POWER BEFORE SERVICING MULTIPLE POWER SOURCES MAY BE PRESENT FAILURE TO DO SO MAY CAUSE PROP ERTY DAMAGE PERSONAL INJURY OF DEATH WARNING ONLY INDIVIDUALS MEETING THE REQUIREMENTS OF AN ENTRY LEVEL