Chapter 1 Meter Introduction 6,Meter Overview 6,Packing List 7. Intended Use 7,Chapter 2 Meter Basics 8,Using the Universal Power Adapter 8. Attaching the Electrode Stand 9,Meter Connections 10. Meter Keypad 11,Function Keys 12,Numeric Keypad 12. Measurement Modules 13,Module Measurement Capabilities 13.
Preconfigured Meter and Module Options 13,Inserting and Removing Modules 14. Module Removal 14,Module Connections 15,Measurement Display Options 16. Single Dual or Multiple Channel Displays 16,Measurement Display Examples 18. Additional Measurement Display Icons 19,pH Electrode Condition Icon 14. Customizing the Display 21,Meter and Module Maintenance 21.
Chapter 3 Meter Setup Menus 22,Main Setup Menu 22,Channel 1 4 Setup Menus 23. Method Menu 25,Temperature Menu 27,Instrument Settings Setup Menu 29. Log View Menu 31,Data Log 31,Calibration Log 32,Diagnostics Menu 33. Chapter 4 pH pH ISE and pH LogR Measurement Modules 34. Connecting Electrodes to the Module 34,Channel 1 4 Setup Menus 36. Mode Menus for pH mV Relative mV ORP and ISE 36,pH Calibration 40.
pH Calibration Editing 40,Relative mV Calibration 42. ORP Calibration 43,ISE Calibration pH ISE Module Only 44. ISE Calibration Editing 44,Temperature Calibration 45. ATC Probe Temperature Calibration 45,Manual Temperature Entry 45. LogR Temperature Calibration pH LogR Module Only 46. Incremental Techniques pH ISE Module Only 48,Single Known Addition 49.
Double Known Addition 50,Single Known Subtraction 51. Double Known Subtraction 52,Single Analate Addition 53. Single Analate Subtraction 54,Chapter 5 Conductivity Measurement Module 56. Connecting Electrodes to the Module 56,Channel 1 4 Setup Menus 57. Mode Menus for Conductivity TDS Salinity and Resistivity 57. Conductivity Calibration 61,Automatic or Direct Conductivity Calibration 61.
Cell Constant Entry Manual Conductivity Calibration 62. Conductivity Verification Procedure 63,Chapter 6 RDO DO Measurement Module 64. Connecting Electrodes to the Module 64,Channel 1 4 Setup Menus 65. Mode Menus for Dissolved Oxygen 65,RDO Electrode Information 66. Dissolved Oxygen Calibration 67,Water Saturated Air Calibration 67. Air Saturated Water Calibration 68,Manual Winkler Calibration 68.
Set Zero Calibration 69,Chapter 7 Meter Measurements 70. Measurement Overview 70,Measurement Read Types 72,Auto Read 72. Single Shot 73,Continuous 73,Measurement Procedure 74. Measurement Tip Using the Electrode Holder 75,Chapter 8 Data Transfer and Software Updates 76. Data Transfer Settings 76,Installing the VERSA STAR USB Driver Software 78.
Meter Software Upgrade Procedure 79,Computer and Printer Compatibility 80. Computer Requirements 80,Printer Requirements 80,VERSA STAR Meter Remote Control Protocols 80. Remote Control Commands 81,Chapter 9 Customer Services 88. Troubleshooting Tips 89,Meter Self Test 90,WEEE Compliance 91. Declaration of Conformity 92,Meter Specifications 93.
Ordering Information 99,VERSA STAR Selectable Meter Components 99. VERSA STAR Preconfigured Meter Systems 99, VERSA STAR Meter Accessories Electrodes and Solutions 101. Appendix A Channel Specific Settings and Features 104. General Mode Settings 104,Sample ID 104,Stability 105. Averaging 105,Alarms 105,pH and ISE Mode Settings 106. Buffer Group and Automatic Buffer Recognition 106,Isopotential Value 107.
Linear Regression 108,Blank Correction 109,Low Level Stability 110. LogR Temperature Technology 111,LogR Temperature Accuracy 111. Advanced pH Electrode Diagnostics using LogR Technology 112. Conductivity TDS Salinity and Resistivity Mode Settings 116. Cell Constant K and Automatic Conductivity Calibration 116. Orion Conductivity Standard Values from 0 C to 50 C 117. Reference Temperature Temperature Compensation and Temperature Coefficient 119. Cell Type 120,TDS Factor 120,Salinity Type 120,Dissolved Oxygen Settings 121. Barometric Pressure Compensation 121,Salinity Correction 121. Meter Introduction,Meter Overview, Thermo Scientific Orion VERSA STAR meters offer four channels that can be configured in.
any combination through their modular design Measurement modules are automatically. recognized by the meter and can be added or removed from channels at any time. Five VERSA STAR measurement modules are available, VSTAR PH module measures pH mV relative mV or ORP with temperature. VSTAR ISE module measures concentration using an ion selective electrode ISE pH. mV relative mV or ORP with temperature, VSTAR LR module measures pH mV or ORP with temperature including LogR. technology that measures sample temperature using a glass bulb pH electrode no. separate ATC probe needed in samples, VSTAR CND module measures conductivity TDS salinity or resistivity with temperature. VSTAR RD module measures dissolved oxygen as percent saturation or concentration. with temperature using either RDO optical or polarographic probes. Get the information you need quickly and easily from the large bright color display which can. be personalized to show only the measurements and information you need Display one to four. measurements simultaneously in any combination, When setting up the meter or performing a calibration step by step instruction prompts and a. numeric keypad with menu specific function keys make meter operation fast and simple The. meter interface can be set to a variety of languages. 6 Orion VERSA STAR Meter User Manual Thermo Scientific. Chapter 1 Meter Introduction,Packing List, VERSA STAR meters and meter kits include the following items.
Meter attached electrode stand,Universal power adapter. Literature CD,Printed quick start guide,USB computer cable. Meter test certificate, Each VERSA STAR meter is fully tested and certified by Thermo Fisher Scientific and a certificate. of calibration is included with each meter and measurement module system. For specific measurement module and kit contents refer to the Ordering Information section. Visit our website at www thermoscientific com OrionMeters to download the complimentary. Thermo Scientific Orion Star Com data transfer computer software and latest VERSA STAR. USB driver,Intended Use, Please read this reference guide thoroughly Any use outside of these instructions may. invalidate the meter warranty and cause permanent damage to the meter. Thermo Scientific Orion VERSA STAR Meter User Manual 7. Meter Basics,Using the Universal Power Adapter, A universal power adapter Catalog Number STARA PWR with US EU UK and China plug.
plates is included with the VERSA STAR meter, This universal power adapter is specifically for use with VERSA STAR meters Use of other. power adapters can damage the meter and void the warranty. 1 Select the appropriate plug plate for the power outlet that will be used. 2 Remove the clear plastic cover from the groove on the back of the power adapter. 3 Slide the appropriate plug plate into the groove on the back of the power adapter. 4 Connect the assembled power adapter to a power outlet and the meter input labeled. POWER The use of a surge protector or uninterrupted power supply UPS is also. recommended, 8 Orion VERSA STAR Meter User Manual Thermo Scientific. Chapter 2 Meter Basics,Attaching the Electrode Stand. The electrode stand can be attached to either side of the meter and up to two stands can be. attached to each meter A weighted base Catalog Number STARA HB is also available to. support the stand without a meter, 1 Open the box containing the electrode stand The box will include a base plate electrode. arm pivot pin electrode holder ATC spacer and RDO clip. 2 Turn the meter over with the meter display facing down on a clean dry surface. 3 Identify the side of the meter that the stand will be installed on and remove the screw. between the circles on that side of the meter, 4 Align the base plate of the stand with the circles on the meter.
5 Replace the screw from step 3 to attach the base plate to the meter. 6 Turn the meter over with the meter display facing up. 7 Insert the electrode arm into the metal post on the base plate. 8 Connect the electrode holder to the electrode arm using the pivot pin. Thermo Scientific Orion VERSA STAR Meter User Manual 9. Chapter 2 Meter Basics,Meter Connections, 1 Connect a Thermo Scientific Orion Star stirrer probe Catalog Number 096019 to the. STIRRER 1 and or STIRRER 2 input on the meter The Orion Star stirrer probes are. controlled and powered by the meter eliminating the need for magnetic stir bars and plates. The STIRRER 1 and STIRRER 2 inputs can be assigned to each channel and the. stirrer speed can be set using the Instrument Settings setup menu. 2 For data transfer to a computer connect a cable to the MINI B USB or RS232 input on the. meter and the corresponding input on the computer, 3 For data transfer to a printer connect a cable to the MICRO AB USB or RS232 input on the. meter and the corresponding input on the printer, 4 Review the meter output settings Communication Printing Printing Format in the. Instrument Settings setup menu to ensure the meter output settings are correct to interface. the meter with a printer or computer, The following image shows the meter back panel without any modules connected. MICRO AB USB MINI B USB,STIRRER 1 STIRRER 2,RS232 POWER.
Connector Function,MICRO AB USB Use for data output to a USB printer. STIRRER 1 Accepts an Orion Star stirrer probe which is controlled and powered by the meter. Use the RS232 cable Cat No 1010053 for bi directional communication and data. transfer via RS232, Use the USB cable included with meter for bi directional communication and data. MINI B USB,transfer via USB, STIRRER 2 Accepts the Orion Star stirrer probe which is controlled and powered by the meter. Connect the universal power adapter included with meter to power the meter. Remove and reconnect the power adapter to reboot the meter. GND Ground receptacle used to reduce interference generated by other equipment. 10 Orion VERSA STAR Meter User Manual Thermo Scientific. Chapter 2 Meter Basics,Meter Keypad, The VERSA STAR meter keypad includes menu specific function keys that update on the display. for fast and efficient meter operation a numeric keypad to facilitate data entry and shortcut keys. for easy navigation to the measurement setup calibration data log and calibration log menus. Key Icon and Name Function, Press the power key to enter the standby meter mode with screen saver Press.
the power key a second time to enter the active meter mode. Press the f1 f2 and f3 function keys to perform the action shown above each key. on the display, Press the channel key when two or more modules are connected to the meter to. change the measurement display to show each channel individually or a. channel combination of two or more channels simultaneously. Press the measure esc key in the AUTO READ measurement mode to start a. new measurement Press to escape to the measurement mode from other modes. measure esc and menus Press to enter a value of one 1 when using the numeric. Press the up arrow key to scroll up through a list of items. Press to enter a value of two 2 when using the numeric keypad. Press the setup key to enter the setup menu from the measurement mode. Press to enter a value of three 3 when using the numeric keypad. Press the cal key to enter the calibration menu from the measurement mode. Press to enter a decimal point when using the numeric keypad. Press the left arrow key to scroll left through a list of items. Press to enter a value of four 4 when using the numeric keypad. left arrow, Thermo Scientific Orion VERSA STAR Meter User Manual 11. Chapter 2 Meter Basics,Key Icon and Name Function,Press the enter key to select an option. Press to enter a value of five 5 when using the numeric keypad. Press the right arrow key to scroll right through a list of items. Press to enter a value of six 6 when using the numeric keypad. right arrow, Press the stirrer key to turn the stirrer probe on and off in the continuous or. timed measurement mode and the calibration edit mode. stirrer Press to make a value positive or negative when using the numeric keypad. Press the mode key to change the measurement mode of a channel. Press to enter a value of seven 7 when using the numeric keypad. Press the down arrow key to scroll down through a list of items. Press to enter a value of eight 8 when using the numeric keypad. down arrow, Press the log view key to access the data log and calibration log from the.
measurement mode, log view Press to enter a value of nine 9 when using the numeric keypad. Press the log print key to manually log print or log and print a measurement. depending on the selected measurement mode and data output settings. log print Press to enter a value of zero 0 when using the numeric keypad. Function Keys, The following image shows the f1 f2 and f3 keys with their corresponding actions above each. function key on the meter display Pressing the f1 Cal key will prompt the meter to enter the. calibration mode Pressing the f2 Sample ID key will prompt the meter to enter the sample ID. setup mode Pressing the f3 Setup key will prompt the meter to enter the main setup menu. Thermo Scientific Orion V ERSA S TAR Meter User Manual 9 Chapter 2 Meter Basics Meter Connections 1 Connect a Thermo Scientific Orion Star stirrer probe Catalog Number 096019 to the STIRRER 1 and or STIRRER 2 input on the meter The Orion Star stirrer probes are controlled and powered by the meter eliminating the need for magnetic stir bars and plates The STIRRER 1