Transcription:

System Configuration,Support Software,NX series Controller. Peripheral USB port,Supply Unit CPU Unit,EtherNet IP. Built in EtherNet IP port,EtherCAT Network,Built in EtherCAT port. EtherCAT Configuration, Slave Terminal Servo Drive encoder General purpose slaves. input slaves,Ordering Information,Applicable standards.
Refer to the OMRON website www ia omron com or ask your OMRON representative for the most recent applicable standards for each model. NX701 CPU Units,Specifications,Product Name Current Power consumption Model. Program capacity Memory capacity for variables Number of motion axes. 256 NX701 1700,Retained during power interruption,Not retained during power interruption. 128 NX701 1600,40 W including SD Memory Card,NX701 80 MB. and End Cover,Connection 256 NX701 1720,CPU Units 4 MB. Retained during power interruption,Not retained during power interruption.
including Memory for CJ series Units,128 NX701 1620. Accessories,The following accessories come with the CPU Unit. Product Name,NX701 1 00 NX701 1 20,Battery CJ1W BAT01. End Cover NX END01 must be attached to the right end of the CPU Rack. Fan Unit NX FAN01,SD Memory Card,Flash Memory,Power Supply Units. One Power Supply Unit is required for each Rack,Power supply capacity.
Product Name Model,voltage Total power 24 VDC service Maintenance. RUN output,consumption power supply forecast monitor. AC Power Supply Unit 100 to 240 VAC 90 W NX PA9001. DC Power Supply Unit 24 VDC 70 W NX PD7001,Automation Software Sysmac Studio. Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio DVDs and licenses are available. individually Each model of licenses does not include any DVD. Product name Specifications Number of Model, The Sysmac Studio is the software that provides an integrated environment for setting. DVD SYSMAC SE200D, programming debugging and maintenance of machine automation controllers including NJ Media only.
NX series CPU Units NY series Industrial PC EtherCAT Slaves and HMI. Sysmac Studio runs on the following OS,Sysmac Studio. Windows 7 32 bit 64 bit version Windows 8 32 bit 64 bit version. Standard Edition, Windows 8 1 32 bit 64 bit version Windows 10 32 bit 64 bit version. Ver 1 1 license 1 SYSMAC SE201L, The Sysmac Studio Standard Edition DVD includes Support Software to set up EtherNet IP. Units DeviceNet slaves Serial Communications Units and Support Software for creating. screens on HMIs CX Designer,For details refer to your OMRON website. Sysmac Studio, Sysmac Studio Team Development Option is a licence to enable the project version control.
Team Development 1 license 1 SYSMAC TA401L, 1 Multi licenses are available for the Sysmac Studio 3 10 30 or 50 licenses. 2 This product is a license only You need the Sysmac Studio Standard Edition DVD media to install it. This option can be used by applying the Team Development Option to Sysmac Studio version 1 20 or higher. Project version control function is supported by CPU Unit version 1 16 or later. Collection of software functional components Sysmac Library. Please download it from following URL and install to Sysmac Studio. http www ia omron com sysmac library,Typical Models. Product Features Model, The Vibration Suppression Library is used to suppress residual vibration caused by the operation of. Vibration Suppression Library machines,SYSMAC XR006. The Device Operation Monitor Library is used to monitor the operation of devices such as air cylinders. Device Operation Monitor Library sensors motors and other devices. SYSMAC XR008, The Dimension Measurement Library is used to dimension measurement with ZW 8000 7000 5000.
Dimension Measurement Library Confocal Fiber Displacement Sensor or E9NC TA0 Contact Type Smart Sensor. SYSMAC XR014, Recommended EtherCAT and EtherNet IP Communications Cables. Use a straight STP shielded twisted pair cable of category 5 or higher with double shielding aluminum tape and braiding for EtherCAT. For EtherNet IP required specification for the communications cables varies depending on the baud rate. For 100BASE TX 10BASE T use a straight or cross STP shielded twisted pair cable of category 5 or higher. For 1000BASE T use a straight or cross STP cable of category 5e or higher with double shielding aluminum tape and braiding. Cable with Connectors,Recommended,Item Cable length m Model. manufacturer, Cable with Connectors on Both Ends OMRON 0 3 XS6W 6LSZH8SS30CM Y. 0 5 XS6W 6LSZH8SS50CM Y,Standard RJ45 plug type 1, Wire Gauge and Number of Pairs Cable color Yellow 3 1 XS6W 6LSZH8SS100CM Y. AWG26 4 pair Cable, Cable Sheath material LSZH 2 2 XS6W 6LSZH8SS200CM Y.
3 XS6W 6LSZH8SS300CM Y,5 XS6W 6LSZH8SS500CM Y, Cable with Connectors on Both Ends OMRON 0 3 XS5W T421 AMD K. 0 5 XS5W T421 BMD K,Rugged RJ45 plug type 1,Cable color Light blue 1 XS5W T421 CMD K. 2 XS5W T421 DMD K,5 XS5W T421 GMD K,10 XS5W T421 JMD K. Cable with Connectors on Both Ends OMRON 0 5 XS5W T421 BM2 SS. M12 Straight M12 Straight, Shield Strengthening Connector cable 4 1 XS5W T421 CM2 SS. M12 Smartclick Connectors 2 XS5W T421 DM2 SS,Wire Gauge and Number of Pairs Cable color Black.
3 XS5W T421 EM2 SS,AWG22 2 pair cable,5 XS5W T421 GM2 SS. 10 XS5W T421 JM2 SS, Cable with Connectors on Both Ends OMRON 0 5 XS5W T421 BMC SS. M12 Straight RJ45, Shield Strengthening Connector cable 4 1 XS5W T421 CMC SS. M12 Smartclick Connectors,2 XS5W T421 DMC SS,Rugged RJ45 plug type. Cable color Black 3 XS5W T421 EMC SS,5 XS5W T421 GMC SS.
10 XS5W T421 JMC SS, 1 Cables with standard RJ45 plugs are available in the following lengths 0 2 m 0 3 m 0 5 m 1 m 1 5 m 2 m 3 m 5 m 7 5 m 10 m 15 m 20 m. Cables with rugged RJ45 plugs are available in the following lengths 0 3 m 0 5 m 1 m 2 m 3 m 5 m 10 m 15 m. For details refer to the Industrial Ethernet Connectors Catalog Cat No G019. 2 The lineup features Low Smoke Zero Halogen cables for in cabinet use and PUR cables for out of cabinet use Although the LSZH cable is. single shielded its communications and noise characteristics meet the standards. 3 Cable colors are available in yellow green and blue. 4 For details contact your OMRON representative,Cables Connectors. Item Recommended manufacturer Model, Products for EtherCAT or Hitachi Metals Ltd NETSTAR C5E SAB. EtherNet IP 0 5 4P CP 1,Wire Gauge and Number of Cables. 1000BASE T 2 100BASE TX Kuramo Electric Co KETH SB 1. Pairs AWG24 4 pair,Cable SWCC Showa Cable Systems Co FAE 5004 1.
RJ45 Connectors Panduit Corporation MPS588 C 1, Products for EtherCAT or Cables Kuramo Electric Co KETH PSB OMR 3. EtherNet IP JMACS Japan Co Ltd PNET B 3,100BASE TX 10BASE T Wire Gauge and Number of. RJ45 Assembly Connector OMRON,Pairs AWG22 2 pair,Cable XS6G T421 1 3. 1 We recommend you to use the above Cable and RJ45 Connector together. 2 The products can be used only with the NX701, 3 We recommend you to use the above Cable and RJ45 Assembly Connector together. Optional Products and Maintenance Products,Product name Specifications Model.
SD memory card 2GB HMC SD291,Memory Cards SDHC memory card 4GB HMC SD491. SDHC memory card 16GB HMC SD1A1, HMC SD1A1 can be used for a CPU Unit with unit version 1 21 or later. Product name Specifications Model, Battery Set Note 1 The battery is included as a standard accessory with the. Battery for NX701 NJ501 CPU Unit, NJ301 NJ101 2 The battery service life is 2 5 years at 25 C The service. CJ1W BAT01, life depends on the ambient operating temperature and.
NJ NX Series CPU Unit maintenance the power conditions. 3 Use batteries within two years of manufacture, Mounted to the right hand side of One End Cover is provided as a standard accessory with each. NX Series CPU Racks CPU Unit and I O Interface Unit. DIN Track Accessories,Product name Specifications Model. DIN Track Length 0 5 m Height 7 3 mm PFP 50N,Length 1 m Height 7 3 mm PFP 100N. Length 1 m Height 16 mm PFP 100N2, There are 2 stoppers provided with CPU Units and I O Interface Units as standard accessories to secure the. Units on the DIN Track,Digital Input Units,Specification.
Product Name Number Internal I O Rated input ON OFF Model. I O refreshing method,of points common voltage response time. DC Input Unit 12 to 24 VDC Switching Synchronous I O refreshing and Free 20 s max 400 s max NX ID3317. NPN Run refreshing NX ID3343,24 VDC 100 ns max 100 ns max. Input refreshing with input changed time only NX ID3344. 12 to 24 VDC Switching Synchronous I O refreshing and Free 20 s max 400 s max NX ID3417. PNP Run refreshing NX ID3443,100 ns max 100 ns max. Input refreshing with input changed time only NX ID3444. NPN NX ID4342,Screwless Clamping 8 points 24 VDC, PNP Switching Synchronous I O refreshing and Free NX ID4442. Terminal Block 20 s max 400 s max,12 mm Width NPN Run refreshing NX ID5342.
PNP NX ID5442,DC Input Unit, For both Switching Synchronous I O refreshing and Free. 16 points 24 VDC 20 s max 400 s max NX ID5142 1,NPN PNP Run refreshing. M3 Screw Terminal,Block 30 mm Width,DC Input Unit,16 points NX ID5142 5. For both Switching Synchronous I O refreshing and Free. 24 VDC 20 s max 400 s max,NPN PNP Run refreshing,32 points NX ID6142 5. MIL Connector,30 mm Width,DC Input Unit, For both Switching Synchronous I O refreshing and Free.
32 points 24 VDC 20 s max 400 s max NX ID6142 6,NPN PNP Run refreshing. Fujitsu Connector,30 mm Width,AC Input Unit,200 to 240 VAC 50 60 Hz. 4 points Free Run refreshing 10 ms max 40 ms max NX IA3117. 170 to 264 VAC 3 Hz,Screwless Clamping,Terminal Block. 12 mm Width, To use input refreshing with input changed time the EtherCAT Coupler Unit with unit version 1 1 or later and the Sysmac Studio version 1 07 or. higher are required,Digital output Units,Specification.
Product Name Number Internal I O Maximum value Rated ON OFF Model. I O refreshing method, of points common of load current voltage response time. Transistor Output NPN 0 5 A point Output refreshing with specified time 300 ns max NX OD2154. Unit 2 points 24 VDC,PNP 1 A Unit stamp only 300 ns max NX OD2258. 0 1 ms max,12 to 24 VDC NX OD3121,0 8 ms max,300 ns max. 0 5 A point 300 ns max,2 A Unit 0 5 ms max,4 points NX OD3256. 1 0 ms max,Screwless Clamping 300 ns max,Terminal Block PNP NX OD3257.
300 ns max,12 mm Width,2 A point Switching Synchronous 0 5 ms max. 8 A Unit I O refreshing and Free Run refreshing 1 0 ms max. 0 1 ms max,NPN 12 to 24 VDC NX OD4121,0 8 ms max,0 5 ms max. PNP 24 VDC NX OD4256,0 5 A point 1 0 ms max,4 A Unit 0 1 ms max. NPN 12 to 24 VDC NX OD5121,0 8 ms max,0 5 ms max,PNP 24 VDC NX OD5256. 1 0 ms max,Transistor Output,0 1 ms max,NPN 12 to 24 VDC NX OD5121 1.
0 8 ms max,0 5 A point Switching Synchronous,5 A Unit I O refreshing and Free Run refreshing. 0 5 ms max,PNP 24 VDC NX OD5256 1,1 0 ms max,M3 Screw Terminal. Block 30 mm Width,Transistor Output 0 1 ms max,Unit NPN 12 to 24 VDC NX OD5121 5. 0 8 ms max,0 5 A point,0 5 ms max,PNP 24 VDC NX OD5256 5. 1 0 ms max,Switching Synchronous,I O refreshing and Free Run refreshing.
0 1 ms max,NPN 12 to 24 VDC NX OD6121 5,0 5 A point 0 8 ms max. 32 points 2 A common,4 A Unit 0 5 ms max,MIL Connector PNP 24 VDC NX OD6256 5. 30 mm Width 1 0 ms max,Transistor Output,0 5 A point. Switching Synchronous 0 1 ms max,32 points NPN 2 A common 12 to 24 VDC NX OD6121 6. I O refreshing and Free Run refreshing 0 8 ms max,Fujitsu Connector.
30 mm Width,Relay Output Unit,N O 250 VAC 2 A cos 1 NX OC2633. 250 VAC 2 A cos 0 4 15 ms max 15,2 points Free Run refreshing. 24 VDC 2 A ms max,N O N C 4 A Unit NX OC2733,250 VAC 2 A cos 1. 250 VAC 2 A cos 0 4 15 ms max 15,8 points N O Free Run refreshing NX OC4633. Screwless Clamping 24 VDC 2 A ms max,Terminal Block 12 mm 8 A Unit.
Width 24 mm Width, To use input refreshing with input changed time the EtherCAT Coupler Unit with unit version 1 1 or later and the Sysmac Studio version 1 07 or. higher are required,Digital Mixed I O Units,Specification. Product Name Number of Internal I O Maximum value of Model. I O refreshing method ON OFF response time,points common load current. DC Input Transistor,Output Unit Outputs,Outputs NPN Outputs. 0 1 ms max 0 8 ms max,Inputs 12 to 24 VDC NX MD6121 5.
For both NPN PNP Inputs 24 VDC,Outputs 20 s max 400 s max. Switching Synchronous I O,refreshing and Free Run,refreshing. 16 points Outputs,Outputs PNP,Outputs 24 VDC 0 5 ms max 1 0 ms max. Inputs NX MD6256 5,Inputs 24 VDC Inputs,For both NPN PNP. MIL Connector 20 s max 400 s max,30 mm Width,DC Input Transistor.
Output Unit,Outputs Outputs,Outputs NPN Outputs Switching Synchronous I O. 16 points 0 1 ms max 0 8 ms max, Inputs 12 to 24 VDC refreshing and Free Run NX MD6121 6. Inputs Inputs,For both NPN PNP Inputs 24 VDC refreshing. 16 points 20 s max 400 s max,Fujitsu Connector,30 mm Width. High speed Analog Input Units,Specifications,Trigger input.
NX7 5 Recommended EtherCAT and EtherNet IP Communications Cables Use a straight STP shielded twisted pair cable of category 5 or higher with double shielding aluminum tape and braiding for EtherCAT For EtherNet IP required specification for the communications cables varies depending on the baud rate