Transcription:

The information in this manual is subject to change without notice. Throughout this manual the following notes are used to alert you to safety considerations. ATTENTION Identifies information about practices or circumstances that can lead to personal. injury or death property damage or economic loss, Important Identifies information that is critical for successful application and understanding of the product. ATTENTION Only qualified electrical personnel familiar with the construction and operation of. this equipment and the hazards involved should install adjust operate or service this equipment. Read and understand this manual and other applicable manuals in their entirety before. proceeding Failure to observe this precaution could result in severe bodily injury or loss of life. ATTENTION DC bus capacitors retain hazardous voltages after input power has been. disconnected After disconnecting input power wait five 5 minutes for the DC bus capacitors. to discharge and then check the voltage with a voltmeter to ensure the DC bus capacitors are. discharged before touching any internal components Failure to observe this precaution could. result in severe bodily injury or loss of life, ATTENTION The drive can operate at and maintain zero speed The user is responsible for. assuring safe conditions for operating personnel by providing suitable guards audible or visual. alarms or other devices to indicate that the drive is operating or may operate at or near zero. speed Failure to observe this precaution could result in severe bodily injury or loss of life. ATTENTION Do not install modification kits with power applied to the drive Disconnect and. lock out incoming power before attempting such installation or removal Failure to observe this. precaution could result in severe bodily injury or loss of life. ATTENTION The user must provide an external hardwired emergency stop circuit outside of. the drive circuitry This circuit must disable the system in case of improper operation. Uncontrolled machine operation may result if this procedure is not followed Failure to observe. this precaution could result in bodily injury, ATTENTION The user is responsible for conforming with all applicable local national and. international codes Failure to observe this precaution could result in damage to or destruction. of the equipment, DeviceNet is a trademark of the Open DeviceNet Vendor Association. ControlNet is a trademark of ControlNet International Ltd. PROFIBUS is a trademark of PROFIBUS International, GV3000 SE AutoMax RPM and Reliance are trademarks of Rockwell International.
1999 Rockwell International Corporation,Preface VII. Chapter 1 Starting Up the Drive for Volts Hertz Regulation. 1 1 Preparing for Start Up Volts Hertz 1 2,1 2 Start Up Procedure Volts Hertz 1 3. Chapter 2 Starting Up the Drive for Vector Regulation. 2 1 Preparing for Start Up Vector 2 2,2 2 Start Up Procedure Vector 2 3. Chapter 3 Using the Keypad Display to Program Monitor and Control the Drive. 3 1 Monitor Mode 3 2,3 1 1 Displaying the Selected Reference 3 2. 3 1 2 Entering the Manual Speed Reference 3 3,3 2 Program Mode 3 3.
3 3 Drive Control 3 4,3 4 The Display 3 4,3 4 1 Display Range 3 4. 3 4 2 Scaling the Manual Reference Speed Display and. Reference Display Using P 028 3 5,3 5 The Keypad 3 6. 3 6 Drive Status LEDs 3 8,Chapter 4 Programming Reference. 4 1 Parameter Menus 4 1,4 2 Parameter Types 4 2,4 3 Displaying or Changing Parameter Values 4 3. 4 4 Ensuring Program Security 4 5,4 5 First Menu Parameters 4 6.
4 5 1 First Menu General Parameter Descriptions P 000 to P 006 4 6. 4 6 Second Menu Parameters 4 11,4 6 1 Entering the Second Menu Password 4 11. 4 6 2 Second Menu General Parameter Descriptions P 007. to P 099 4 14, 4 6 3 Second Menu V Hz Parameter Descriptions H 000 to. H 022 4 57, 4 6 4 Second Menu Vector Parameter Descriptions U 000 to. U 048 4 70, Chapter 5 Troubleshooting the Drive Using Error Codes. 5 1 Identifying Alarm Codes and Recovering 5 2,5 2 Identifying Fault Codes and Recovering 5 3.
Table of Contents I, 5 3 Accessing Reading and Clearing the Faults in the Error Log 5 6. 5 4 Identifying Fatal Fault Codes and Recovering 5 9. Appendix A Alphabetical Listing of Parameters A 1,Appendix B Record of User Parameter Settings B 1. Appendix C Power Module Dependent Parameter Default Values. 230 V Series C 1,Appendix D Default Parameter Settings D 1. Appendix E Configuring the Digital Inputs When the RMI Board is. Installed in the Drive E 1, Appendix F Using the Terminal Strip Analog Input F 1. Appendix G Drive Regulation Overview G 1, II GV3000 SE 230 VAC Drive Software Reference Version 6 04.
List of Figures,Figure 3 1 Keypad Display 3 1,Figure 3 2 Example of a Monitor Mode Display 3 2. Figure 3 3 Example of a Program Mode Display 3 4,Figure 4 1 Parameter Menu Structure 4 2. Figure 4 2 Analog Output Selection and Setting 4 21. Figure 4 3 Trim Reference Source Selection 4 22,Figure 4 4 Draw and Trim Gain 4 23. Figure 4 5 S Curves 4 25,Figure 4 6 Typical Preset Operation 4 34. Figure 4 7 Drive Start Stop and Running Status when Configured for. Edge Control vs Level Control 4 44, Figure 4 8 Sample Alarm Circuit for 1 20 HP Drives Using the Level.
Sense Enable Feature 4 45, Figure 4 9 Signal Selection for Network Output Registers 4 54. Figure 4 10 Volts Hertz Ratio 4 57,Figure 4 11 Torque Boost Voltage 4 59. Figure 4 12 Avoidance Frequency Band 4 63,Figure 4 13 Volts Hertz Curve Selection 4 67. Figure 4 14 Motor Equivalent Circuit Diagram for Calculating Rotor Time. Constant 4 82, Figure 4 15 Outer Control Loop Proportional Trim 4 92. Figure F 1 Terminal Strip Analog Input F 1, Figure F 2 Analog Input Conversion Scaling Speed and Trim Reference F 3.
Figure G 1 Volts Hertz Regulator Block Diagram G 3. Figure G 2 Flux Vector Control Block Diagram G 4, Figure G 3 Sensorless Vector Control Block Diagram G 4. Figure G 4 Vector Regulator Reference Detail G 5,Figure G 5 Vector Regulator Speed Loop Detail G 6. Figure G 6 Vector Speed PI and Iq Reference Limit Selection G 7. Figure G 7 Outer Control Loop Block Diagram G 8,Table of Contents III. List of Tables,Table 3 1 Display Range Examples 3 5. Table 3 2 Drive Status LEDs 3 8,Table 3 2 Monitor Mode LEDs 3 9.
Table 4 1 Speed Reference Source Based on P 000 and AUTO MAN. Key Status 4 7, Table 4 2 Function Selection for Digital Inputs 6 7 and 8 4 14. Table 4 3 Acceptable P 007 and P 008 Selection Combinations 4 18. Table 4 4 Preset Speed Digital Inputs 4 33,Table 4 5 Faults That Can Be Auto Reset 4 37. Table 4 6 AUTO MAN Key Status Based on P 000 and P 052 4 41. Table 4 7 STOP RESET Key Status Based on P 000 and P 055 4 46. Table 5 1 List of Alarm Codes 5 2,Table 5 2 List of Fault Codes 5 3. Table 5 3 Fatal Fault Codes That Can Be Reset 5 9, Table F 1 Analog Input Conversion Scaling for Speed or Trim Reference F 2. Table F 2 Analog Input Conversion Scaling for Torque Reference F 4. Table of Contents V, This manual is a start up and programming reference guide for the version 6 04.
GV3000 SE Sensorless Enhanced drive The drive can be set up for either volts. per hertz V Hz or vector regulation This manual provides a start up procedure for. The start up procedures are followed by reference information This information. includes a complete list of all parameters and a description of the keypad display. You will need to know to use the keypad to perform the start up procedures. described in chapters 1 and 2 If you do not refer to chapter 3 first. For drives that will be set up for V Hz regulation go to chapter 1 for the start up. For drives that will be set up for vector regulation go to chapter 2 for the start. up procedure, For a description of all the parameters go to chapter 4. For troubleshooting guidelines go to chapter 5, For a description of the drive hardware refer to the GV3000 SE 230 VAC 1 20. HP Drive Hardware Reference Installation and Troubleshooting instruction. manual D2 3388,Getting assistance from Reliance Electric. If you have any questions or problems with the products described in this insruction. manual contact your local Reliance Electric sales office For technical assistance. call 1 800 726 8112,Preface VII,Starting Up the Drive. for Volts Hertz Regulation, This chapter describes the basic start up procedure for drives which utilize open loop.
V Hz regulation V Hz regulation is the default method of regulation You do not. need to select it, If you are starting up a drive which will perform vector regulation refer to the vector. start up procedure in chapter 2 0 instead Do not perform the start up procedure in. this chapter, The start up procedure below provides step by step instructions for. powering up,checking monitor mode displays,accessing program mode. configuring General parameters designated with a P. configuring specific V Hz parameters designated with an H. checking motor rotation direction,running the drive. This start up procedure describes how to program the minimum set of parameters. that usually need to be programmed for applications using V Hz regulation Once. you program these parameters their values are retained even if power is lost You. only need to re program them if you want to change how the drive operates. Your application may require programming other parameters in addition to the ones. described in this start up procedure Refer to chapter 4 for a description of all the. parameters to verify whether you need to program any additional parameters as. well Appendix A provides a list of parameters listed alphabetically. Throughout this manual you will see references to parameter names and the. numbers that identify them for the drive This manual uses the same format that will. be shown on the keypad display to refer to parameters. where nnn is a number,P designates General parameters.
U designates Vector parameters,H designates Volts Hertz parameters. r designates optional RMI parameters, Starting Up the Drive for Volts Hertz Regulation 1 1. 1 1 Preparing for Start Up Volts Hertz, Read through the following sections to prepare for the start up procedure. What You Need To Know, You must be qualified to perform the procedure and be familiar with V Hz. regulation, You should be familiar with the keypad display If you are not familiar with the.
keypad display refer to chapter 3 which describes it. What You Need To Do, Complete all hardware installation as described in the hardware reference. manual This includes connecting input power input transformers if required. disconnects fuses and the terminal strip on the drive. Record the following motor data from each motor nameplate for use during the. procedure Space is provided for recording information from three motors. Motor rated amps,Motor rated volts,Motor base frequency. Motor rated amps,Motor rated volts,Motor base frequency. Motor rated amps,Motor rated volts,Motor base frequency. Connect the drive to the motor, Check that you have not been prevented from programming the drive If the.
PASSWORD LED on the keypad is on programming has been prevented in. parameter P 051 Programming Disable Refer to section 4 4 in this manual for. the procedure to enable programming,If You Have a Problem. During most of the start up procedure you will be in program mode which is used. to program parameters If you want to stop programming parameters you can exit. program mode You can do this by pressing the PROGRAM key until the. PROGRAM LED turns off This will place the keypad display in monitor mode the. default You can read more about these modes in chapter 3. 1 2 GV3000 SE 230 VAC Drive Software Reference Version 6 04. To Restore a Default Parameter Value after Writing over It. If you enter the wrong value while programming parameters you can restore the. default if you have not yet pressed the ENTER key To do so. 1 Press the PROGRAM key, 2 Press the ENTER key The default value of the parameter will be displayed. again You can select it with ENTER or enter a new one and press ENTER. To Restore All the Default Values to General P Parameters. If you need to restore all the default values for General P parameters after. programming them you can do so using the Restore Defaults parameter P 050. 1 2 Start Up Procedure Volts Hertz, This section describes the start up procedure for drives set up for V Hz regulation. Before using this procedure you should have read section 1 1 for information you. need to know before working with the drive,Step 1 Power Up the Drive. This step verifies that the drive powers up and passes the power up diagnostics. After the drive passes the diagnostics the keypad display automatically enters. monitor mode with speed displayed,Turn power on,The initial display shows SELF with all.
monitor mode and status LEDs on indicating,AUTO Forward. MAN Reverse the drive is performing power up,JOG diagnostics. Kw FORWARD,TORQUE REVERSE,Password PROGRAM ENTER,RESET START. After diagnostics are complete 5 6,AUTO Forward,seconds the SPEED LED is on and the. MAN Reverse,keypad display is in monitor mode The,AMPS JOG RUN.
JOG displayed value is zero You can move,Kw FORWARD. PROGRAM ENTER,through the five items accessible in monitor. HP Drive Hardware Reference Installation and Troubleshooting instruction manual D2 3388 Getting assistance from Reliance Electric If you have any questions or problems with the products described in this insruction manual contact your local Reliance Electric sales office For technical assistance call 1 800 726 8112