Transcription:

Data Sheet,Section Sheet,GLOSSARY OF TERMS AND DEFINITIONS. MEDIUM VOLTAGE POWER CABLES 2 4kV AND ABOVE,Single Conductor Cable. Okoguard Non Shielded Okolon TS CPE Type MV 90 CT USE 2 4kV 2 2. Okoguard Shielded Okoseal Type MV 105 CT USE 5 8kV 2 3. Okoguard Shielded Okoseal Type MV 105 5 8 kV 2 4, Okoguard Shielded Okoseal Type MV 105 CT USE 15kV 2 8. Okoguard Shielded Okoseal Type MV 105 15kV 2 9, Okoguard Shielded Okolon TS CPE Type MV 105 CT USE 15kV 2 11. Okoguard Shielded Okoseal Type MV 105 35kV 2 16,Okoguard Shielded Okoseal 69kV 2 18.
Multi Conductor Cable, Okoguard Shielded Okoseal Type MV 105 CT USE 3 C 5 8kV 2 19. Okoguard Shielded Okoseal Type MV 105 CT USE 3 C 15kV 2 20. Okoguard Non Shielded C L X Type MV 90 or MC HL CT USE 2 4kV 2 21. Okoguard Shielded C L X Type MV 105 or MC HL CT USE 5 8kV 2 22. Okoguard Shielded C L X Type MV 105 or MC HL CT USE 15kV 2 24. Solid Type PILC 3 C 15kV 2 31,UNDERGROUND RESIDENTIAL DISTRIBUTION CABLE. Okoguard URO J 15kV 2 35,Okoguard URO J 15kV Filled Strand 2 36. Okoguard URO J 25kV 2 39,Okoguard URO J 35kV 2 40,LOW VOLTAGE CABLES TO 2kV. Single Conductor Cable, Okoguard Okolon TS CPE Type RHH or RHW 2 or USE 2 VW 1 600V RW 90 3 1.
Okoguard Okolon TS CPE Type RHH or RHW 2 2000V 3 10. Multi Conductor Cable,C L X Type MC HL for CT USE XHHW 2 600V 4 1. C L X Type MC XHHW 2 600V 4 2,Okonite FMR Okoseal Type TC 600V 4 5. X Olene Okoseal Type TC ER Control Cable XHHW 2 600V 4 8. C L X Type MC for CT USE XHHW 2 600V Control Cable 4 14. C L X Type MC HL for CT USE XHHW 2 600V Control Cable 4 15. Data Sheet,Section Sheet,INSTRUMENTATION CABLES,Okoseal Type P OS 300V 5 2. Okoseal Type P OS C L X 300V 5 3,Type SP OS Instrumentation Cbale 5 13. Okoseal Type SP OS C L X 300V 5 14,Okoseal Type P OS Thermocouple 300V 5 18.
C L X Okoseal Type P OS Thermocouple 300V 5 19,Okoseal N Type P OS 600V 5 29. Okoseal N Type SP OS 600V 5 31,Okoseal N Type P OS C L X Type MC HL 600V 5 40. Okoseal N Type SP OS C L X Type MC HL 600V 5 42,Okobus Type PLTC Type ITC ER Fieldbus Cable. Single Pair Type P OS Multi Pair Type SP OS 5 47,Okobus C L X 5 48. C L X X Olene P OS SP OS 5 49,SPECIAL PURPOSE CABLES.
X Ray Low Noise 65 250kV DC 6 1,X Ray 65 1000kV DC 6 2. Okoguard Aerial Jumper Cable 15kV 6 4, Okoguard Okolon TS CPE 5kV Airport Lighting Cable 6 6. RAILROAD AND TRANSIT SYSTEM CABLES,Armored Signal Cable 7 1. Track Wire 7 6,Tower and Case Wire 7 10,Case Wire 7 11. Nylon Braid Case Wire 7 12,Type DEL 7 17,SPLICING AND TERMINATING PRODUCTS.
C L X Terminating Tool Kit 6 5,Color Code Tables OSL. Miscellaneous Information OSL,OSC Index 02 15,Okoseal Type P OS 300V 5 2. Okoseal Type P OS C L X 300V 5 3,Type SP OS Instrumentation Cbale 5 13. Okoseal Type SP OS C L X 300V 5 14,Okoseal Type P OS Thermocouple 300V 5 18. C L X Okoseal Type P OS Thermocouple 300V 5 19,Okoseal N Type P OS 600V 5 29.
Okoseal N Type SP OS 600V 5 31,Okoseal N Type P OS C L X Type MC HL 600V 5 40. Okoseal N Type SP OS C L X Type MC HL 600V 5 42,Okobus Type PLTC Type ITC ER Fieldbus Cable. Single Pair Type P OS Multi Pair Type SP OS 5 47,Okobus C L X 5 48. X Ray Low Noise 65 250kV DC 6 1,X Ray 65 100kV DC 6 2. Okoguard Aerial Jumper Cable 15kV 6 4, Okoguard Okolon TS CPE 5kV Airport Lighting Cable 6 6.
Armored Signal Cable 7 1,Track Wire 7 6,Tower and Case Wire 7 10. Case Wire 7 11,Nylon Braid Case Wire 7 12,Type DEL 7 17. C L X Terminating Tool Kit 6 5,Color Code Tables OSL. Miscellaneous Information OSL,OSC Index 02 15, INDUSTRY ASSOCIATIONS OKOCLEAR TS Thermosetting Polyolefin low C L X M C L X Marine Shipboard Cable. ABS American Bureau of Shipping smoke zero halogen jacket compound CPE Chlorinated Polyethylene jacketing. AEIC Association of Edison OKOGUARD Okonite s exclusive ethylene pro material. Illuminating Companies pylene rubber EPR based thermosetting CSA Canadian Standards Association An. ANSI American National Standards insulation with an optimum balance of electrical independent organization which implements. Institute and physical properties unequaled in other solid and monitors the commercial and consumer. AREMA American Railway Engineering dielectrics used on power cables rated 600 V electrical product standards The CSA as. and Maintenance of Way Association and above 43rd Anniversary 2011 sures compliance to the various Canadian. ASTM American Society for Testing and OKOLENE Thermoplastic polyethylene or poly Electrical Code requirements. Materials propylene based insulation or jacket CT Designation given to cables meeting UL. ICEA Insulated Cable Engineers compound requirements for cable tray use. Association formerly IPCEA OKONITE Okonite s exclusive ethylene CTC Designation for Centralized Traffic. IEC International Electrotechnical Com propylene rubber EPR based thermo Control Code Line cable. mission setting insulation used up to 2000V CWCMC UL s designation for 600 volt. IEEE Institute of Electrical and OKONITE FMR Okonite s exclusive flame and C L X marine shipboard cable continu. Electronics Engineers moisture resistant ethylene propylene rubber ously welded corrugated MC cable. NEC National Electrical Code EPR insulation used up to 2000V DEL Diesel Electric Locomotive and car. NEMA National Electrical OKOGUARD OKOLON Composite insulation wiring with Okonite insulation and Okolon. Manufacturers Association system consisting of a layer of EPR and covered jacket. NFPA National Fire Protection with a chlorinated thermoset compound EPR Ethylene Propylene Rubber insulating. Association OKO PACK Okonite s unique compact round compound ingredient. GOVERNMENT AGENCIES conductor shape and design ER Exposed Run UL term designating ca. OSHA Occupational Safety and Health OKOSEAL A PVC insulation or jacketing com bles approved for open wire applications. Act administered by U S Dept of pound with excellent resistance to flame and ETFE Modified Ethylene Tetrofluoroethylene. Labor which establishes employee safety most chemicals compound Okozel used for insulation and. standards in all industrial and commercial OKOSEAL N PVC insulated and nylon jackets. establishments jacketed low voltage conductors Type THHN FIELDBUS CABLE High Speed digital sig. RUS Rural Utility Systems of the U S De THWN 2 and TFN nal transmission instrumentation cable. partment of Agriculture formerly REA OKOLON TP CPE Thermoplastic moisture re having specific electrical characteristics. FAA Federal Aviation Administration sistant CPE compound serving as an outer FPL Power limited Fire Protective Signal. EPA Environmental Protection Agency jacket Cable NEC Art 760 300V rated. DOE Department of Energy OKOLON TS CPE Thermoset moisture resis FMR Flame and Moisture Retardant. FERC Federal Energy Regulatory tant flame retardant CPE outer jacket HL Designation given to MC and ITC cables. Commission OKOTHERM Heat resistant silicone rubber meeting NEC and UL requirements for use. based insulation for use in high temperature lo in Division 1 hazardous locations. OKONITE REGISTERED TRADE,cations INSULATION LEVEL 100 Cable for use.
OKOZEL Okonite s name for its ETFE based on grounded systems or where the system is. C L X Continuous Lightweight Exterior, flame and radiation resistant provided with relay protection such that. Welded and corrugated impervious, insulating and jacketing compound grounds faults will be cleared as rapidly as. metallic sheathed cables, P 30 Okolene Okoseal insulated 600V possible but in any case within one minute. LOXARMOR An interlocked S shaped, multiple and single conductor control INSULATION LEVEL 133 Cable for use. armor cable covering normally galvanized,cable on ungrounded or grounded systems or.
steel or aluminum, P 45 Okolene Okoseal Insulated 1000V where the faulted section will be de ener. OKOBON A moisture resistant cable, Multiple Conductor Control Cable gized in a time not exceeding one hour. finish consisting of an aluminum, X OLENE Okonite s name for its XLPE ITC Instrumentation Tray Cable for instru. copolymer tape fused to itself and to an, insulation and jacket mentation control circuits operating 150V. overall jacket,STANDARD TERMS and 5 amps per NEC Article 727.
OKOBUS Fieldbus instrumentation cable, AWG American Wire Gauge based on the cir kcmil A unit of conductor area in thousands. OKOCLEAR TP TPPO Thermoplastic, cular mil system where 1 mil equals 0 001 inch of circular mils Formerly MCM. Polyolefin low smoke zero halogen jacket, CIC Cable in Conduit for buried distribution sys LOCA Loss of Coolant Accident IEEE 383. tems defines test requirements, CIC Circuit Integrity flame retardant cables LCS Longitudinal Corrugated Shield. GLOSSARY continued, MC Metal Clad cable NEC type designa power cables rated over 2kV to reduce VOLTAGE RATING kV industry convention.
tion for power and control cables enclosed electrical stresses and corona to identify voltage levels phase to phase. in a welded and corrugated metallic SEMICONDUCTING An extruded layer or tape voltage. sheath C L X or an interlocking tape ar of such resistance that when applied between VW 1 Basic flammability test for single. mor Loxarmor Article 330 two elements of a cable the adjacent surfaces of conductors employs a tirrill burner applied. MC HL Metal Clad cable listed for hazard the two elements will maintain substantially the intermittently to a Vertical Wire. ous locations same potential XHHW 2 NEC conductor type designation. mil 0 001 inch SHIELD A nonmagnetic metallic material ap for conductors with Heat and Moisture resis. MV Medium Voltage cable NEC designa plied over an insulated conductor s to confine tant thermoset insulation for use in 90 C wet. tion for single multiple conductor the electric field to the insulation or dry locations. insulated cable rated 2001 to 35 000 volts SP OS Multiple Shielded Pairs or Triads with XLPE Cross Linked Polyethylene insulating. NEC Article 328 Overall Shield instrumentation or compound. NPLF Non Power Limited Fire Protective thermocouple extension cable XLPO Cross Linked Polyolefin a thermoset. Signal Cable NEC Art 760 600V rated TC NEC type designation for power and jacket material with low smoke characteris. OKO MARINE UL designation for non ar control tray cable Article 336 tics and is free of halogens. mored Marine Shipboard Cable TFN NEC conductor type designation for PVC Z NEC conductor type designation for. PLTC Type designation for Power insulated nylon jacketed conductors in sizes 18 conductors with ETFE insulation for use in. Limited Tray Cable for use in Class 2 or 3 and 16 AWG for use in dry dry locations. power limited circuits instrumentation locations ZW NEC conductor type designation for. supervisory control and thermocouple ex THERMOCOUPLE CABLE A cable consisting conductors with ETFE insulation for use in. tension of two dissimilar metals or alloys that when elec wet or dry locations. P NS Single pair or triad Non Shielded trically joined at one end can be used to CONDUCTOR IDENTIFICATION. instrumentation or thermocouple extension measure temperature These cables have no INFORMATION. cable voltage rating E 1 Color sequences for utility conductor. P OS Single or multi Pairs or Triads with THHN NEC conductor type designation for PVC identification see Appendix E Table E 1. Overall Shield instrumentation or thermo insulated nylon jacketed conductors for use in ICEA Standard S 73 532 includes green. couple extension cable dry locations and white, POWER LIMITED CIRCUIT Circuit either THWN 2 NEC conductor type designation for E 2 Color sequence for industrial conductor. inherently limited requiring no overcurrent PVC insulated nylon jacketed conductors for use identification see Appendix E Table E 2. protection or limited by a combination of a in 90 C wet or dry locations ICEA Standard S 73 532 excludes green. power source and overcurrent TPPO Thermoplastic Polyolefin a thermoplastic and white. protection jacket material with low smoke characteristics METHOD 1 Conductor identification colored. PVC Polyvinyl Chloride insulating and and is free of halogens compounds with tracers in accordance with. jacketing material which is usually flame UL Underwriters Laboratories An independent the ICEA standard. retardant and resistant to many organization which examines tests lists and pe METHOD 2 Conductor identification neutral. chemicals riodically inspects compounds with tracers in accordance with. P 104 Okonite s identification number is equipment to appropriate standards the ICEA Standard. sued by the Pennsylvania Department of URO J Underground Residential distribution METHOD 3 Conductor identification neutral. Environmental Resources Okoguard EPR insulation Okolene Jacket em or single colored compounds with surface. RHH NEC conductor type designation for ploying a concentric neutral printing of numbers and color designations in. conductors with Heat resistant rubber or USE Underground Service Entrance accordance with the ICEA Standard. XLPE insulation for use in dry locations cable NEC Article 338 METHOD 4 Conductor identification neutral. RHW 2 NEC conductor type designation VERTICAL TRAY FLAME TEST or single colored compounds with surface. for conductors with Heat and Moisture re Conducted per UL IEEE or ICEA procedures to printing of numbers in accordance with the. sistant rubber or XLPE insulation for use demonstrate that a single conductor 1 0 AWG ICEA Standard. Bulletin OSC OKONITE CABLES 102 Hilltop Road Ramsey New Jersey 07446 Phone 201 825 0300 www okonite com THE OKONITE COMPANY STOCK CATALOG In Stock for Immediate Delivery INDEX Data Sheet Section Sheet GLOSSARY OF TERMS AND DEFINITIONS MEDIUM VOLTAGE POWER CABLES 2 4kV AND ABOVE Single Conductor Cable Okoguard Non Shielded Okolon TS CPE Type MV 90 CT USE 2 4kV 2 2 Okoguard